Operations online · Santos --:--:-- BRTSC-TOOL-05
What holds her to the ground?
Give the ship’s particulars or her equipment number, the grade and the anchor, the supply, the repair and the measured diameters. The tool returns the anchors and the cable the rule gives, their masses and loads, the wear against the renewal limit, the supply with its weight and the repair afloat, drawn in four sheets.
- Equipment sheet · PDF · QR code
- Output
- IACS UR A1
- Rule
- ISO 1704
- Loads
- Operations hub, 24/7
- Response
Calculate the equipment number, the anchors and chain cable the rules require, the cable’s mass and loads, wear against the renewal limit, the supply and its weight and repairs afloat, with detailed drawings, a PDF and a shareable link.
The job
Supply01Activity
A supply, a survey for the class or a repair: the steps follow
02Ship
Her particulars give the equipment number, or type the number itself
03Anchor
The model, its mass and how many
The stockless anchor most merchant ships carry: a square central block with its weight low, a flat foot and slim spear-pointed flukes at 40°.
04Chain cable
Its grade, its diameter and how much of it
The rule gives 24 shackles, 660 m for both sides.
05Fittings
The joining shackles, the forerunners and the anchor shackles
Drawings
SC-AC-101Point at a part, or tap it, to read it; every figure follows the cable’s diameter and the anchor’s mass.
Equipment number
IACS UR A13,154EN
EN = Δ^⅔ + 2·B·h + A/10
- Δ^⅔
- 1,698
- 2·B·h
- 1,290
- A/10
- 165
- Band
- 3,040–3,210
What the rule gives
Spek · U3 · Ø 76- Bower anchors
- 2 × 9,300 kg
- Cable, both sides
- 660 m
- Model
- Spek · stockless
- Length × width
- 3,795 × 2,394 mm
- Shackles a side
- 12 × 27.5 m
- Diameter
- 76 mm · U3
- Mass per metre
- 126.5 kg
- Per shackle
- 3,479 kg
- Proof load
- 4,293 kN
- Breaking load
- 6,001 kN
After IACS UR A1 and ISO 1704: the class society’s rules and the equipment certificate govern.
Supply
≈ 32.7 t| Item | Qty | Each | Total |
|---|---|---|---|
| Spek · Ordinary stockless | 2 | 9,300 kg | 18,600 kg |
| Stud-link cable, shackles of 27.5 m | 4 | 3,479 kg | 13,914 kg |
| Kenter joining shackles | 4 | ≈ 46 kg | 185 kg |
Fittings’ weights are estimates from the link’s mass; the maker’s certificate gives the real one.
Against the rule
IACS UR A1- Anchor mass9,300 kgrule 9,300 kg
- Cable diameterØ 76 mm U3rule Ø 76 mm
- Cable length4 × 27.5 mrule 24 × 27.5 m
Certificates & delivery
3 items- Class certificate for each anchor, its mass and proof test stamped
- Class certificate for the cable: grade, proof and breaking tests
- Certificates for the joining shackles, swivels and anchor shackles
- The cable marked at each joining shackle before it is stowed
- Lifting gear and a crane or barge for the heaviest piece
Where she falls in the table
EN 3,040–3,210The cable by diameter
ISO 1704 · U3| Ø mm | kg/m | kg / 27.5 m | Proof kN | Breaking kN |
|---|---|---|---|---|
| 70 | 107.3 | 2,951 | 3,688 | 5,156 |
| 73 | 116.7 | 3,209 | 3,986 | 5,572 |
| 76 | 126.5 | 3,479 | 4,293 | 6,001 |
| 78 | 133.2 | 3,664 | 4,503 | 6,295 |
| 81 | 143.7 | 3,951 | 4,825 | 6,745 |
Holding power by model
274–411 kNIndicative, in firm sand: the bottom, the scope of cable and the pull’s angle govern. Choose a model on its bar.
Share
QRScan the code to reopen this plan.
After IACS UR A1 and ISO 1704: the class society’s rules and the ship’s equipment certificate govern.
A technical sheet for anchors and chain cable, subject to a survey and an official quotation.
02/How to use
Four steps, one sheet you can send.
Results change as you type, and nothing is sent until you decide to send the plan.
- 01
Choose the activity
A supply of anchors, cable and fittings; a survey for the class, gauged and examined; or a repair afloat. The steps follow the choice.
Go to the activity - 02
Give the ship
Her displacement, breadth, freeboard, the height of her houses and her profile area — or the equipment number from her certificate.
Go to the ship - 03
Set the anchors and the cable
The model — Hall, Spek, JIS or Baldt stockless, AC-14 or Pool-N of high holding power — its mass, the rule’s or yours; the cable’s grade, diameter and length; the fittings, the class, the findings or the works.
Go to the anchors - 04
Keep it, share it or attach it
The equipment, drawings, supply list, survey record or repair change as you edit. Copy the link, scan the QR code, save the PDF or send the plan with your request.
Go to the sheet
03/Method
How the sheet is worked out.
The equipment table of IACS UR A1 and the loads of ISO 1704, written into the tool: an excerpt below, every band in the tool.
| EN | Anchor | Cable | U1 · U2 · U3 |
|---|---|---|---|
| 90–110 | 300 kg | 247.5 m | 17.5 · 16 · — |
| 240–280 | 780 kg | 330 m | 28 · 24 · 22 |
| 500–550 | 1,590 kg | 412.5 m | 40 · 34 · 30 |
| 840–910 | 2,640 kg | 467.5 m | 52 · 46 · 40 |
| 1,300–1,390 | 4,050 kg | 522.5 m | 64 · 56 · 50 |
| 1,930–2,080 | 6,000 kg | 577.5 m | 78 · 68 · 60 |
| 2,870–3,040 | 8,700 kg | 632.5 m | 95 · 84 · 73 |
| 4,000–4,200 | 12,300 kg | 687.5 m | 111 · 97 · 87 |
| 5,200–5,500 | 16,100 kg | 742.5 m | 127 · 111 · 97 |
| 7,400–7,900 | 23,000 kg | 770 m | — · 132 · 117 |
| 10,700–11,500 | 33,000 kg | 770 m | — · — · 142 |
- Equipment number
- EN = Δ^⅔ + 2·B·h + A/10, as IACS UR A1 sets it.
- Anchors
- Two bower anchors of the table’s mass; a high holding power anchor may weigh 75% of it.
- Models
- Hall, Spek, JIS and Baldt stockless; AC-14 and Pool-N of high holding power, each with its proportions and fluke angle.
- Cable
- The table’s total length, in shackles of 27.5 m, half on each side.
- Mass
- About 0.0219·d² kg a metre of stud-link cable; a common link about that times 4d.
- Loads
- Proof and breaking loads of ISO 1704 by grade, from the diameter.
- Wear
- Renew at 12% loss of the mean diameter; watch from 10%.
- Windlass
- Continuous pull of 37.5, 42.5 or 47.5·d² N by grade; the brake holds 45% of the breaking load with a stopper.
04/FAQ
Questions we are asked most often.
01What can I plan with the tool?
Three jobs. A supply: the model and mass of the anchors, the cable’s grade, diameter and length, the fittings, with their weights and the certificates they come with. A survey for the class, any of the twelve IACS members: the cable gauged shackle by shackle against the renewal limit, the anchors examined. A repair afloat: the works, their hours and the parts.
02What is the equipment number?
The figure IACS UR A1 sizes a ship’s anchoring equipment by: EN = Δ^⅔ + 2·B·h + A/10, with Δ the moulded displacement at the summer load waterline, B the breadth, h the freeboard amidships plus the height of the houses wider than a quarter of the breadth, and A the profile area above the waterline. Her equipment certificate states it.
03Which table does the tool use?
The equipment table of IACS UR A1: for each band of equipment number, the mass of each of the two bower anchors, the total length of stud-link cable and its diameter in grades U1, U2 and U3. The class society’s own rules and the ship’s certificate govern.
04Which anchor models does the tool draw?
Six: the ordinary stockless Hall, Spek, JIS and Baldt, carried at the table’s mass, and the high holding power AC-14 and Pool-N, at 75% of it. Each is drawn in front and side elevation with its section, from the type’s indicative proportions for the mass; the maker’s drawing governs.
05What is a high holding power anchor?
One proven to hold at least twice what an ordinary stockless anchor of the same mass holds, and approved as such by the class. IACS UR A1 then lets each bower anchor weigh 75% of the table’s mass. The holding power the tool shows is indicative, in firm sand: the bottom, the scope of cable and the angle of the pull govern.
06What do the grades mean?
The steel of the cable: U1 mild steel, U2 special quality and U3 extra special quality, each stronger than the last, so a smaller diameter carries the same load. Most ships today carry U3.
07How are the mass and the loads worked out?
Stud-link cable weighs about 0.0219·d² kg a metre; its proof and breaking loads follow ISO 1704: in grade U3, 0.0196·d²·(44 − 0.08·d) kN proof and 0.0274·d²·(44 − 0.08·d) kN breaking, d in millimetres.
08When must a shackle be renewed?
When the mean diameter at its most worn link, two measurements at right angles, has lost 12% of the nominal — the limit most class rules apply. The tool watches from 10%.
09How are the shackles marked?
At each joining shackle the links either side are painted white and wired: one link each side at the first shackle, two at the second, up to five at the fifth, then the count starts again.
10Does the tool store my data?
No. The data stays in your browser, and nothing is sent until you submit the plan through the contact page and add your details there.